ANTUNCLE
Request a quote

DR 1500W PLUS

High-output full-spectrum + UV/IR, 2-channel control

Factory-direct pricing. Send your room size and target PPFD for a layout recommendation with the quote.

Photon flux (PPF)
4,200 µmol/s
Input power
1500 W
Flowering footprint
4ft x 7ft
Ingress protection
IP65
DR 1500W PLUS
Evidence

What we measured

The three artifacts a lighting plan is actually drawn from. Every figure below comes off our own spec sheet; where we do not have a measurement, the page says so instead of estimating.

Coverage & PPFD

Rated flowering footprint, 4 × 7 ft. Both readings are µmol/m²/s measured 1 ft from canopy (mounting range 6-24 in). The shading illustrates centre-to-edge falloff; it is not a measured grid. A full PPFD map at your mounting height comes with the quote.

7 ft4 ft
1,613centre · µmol/m²/s
1,225average over footprint
2-channel spectrum

2-channel spectrum

Full spectrum white (Samsung LM281B) + 450nm blue + 660nm deep red + 730nm far-red + 395nm UV. Each channel dims on its own — at the fixture or over group control.

Download the full spec sheet (PDF)
Overview

What the DR 1500W PLUS is for

The highest-output flexible-arm fixture: 4,200 µmol/s over a 4ft × 7ft flowering bench, delivering 1,225 µmol/m²/s average at canopy. Two channels rather than three — UV and far-red move together against the white/blue base — which is the right simplification for production rooms running a fixed recipe at high intensity. 2,250W HPS replacement.

What you get

  • 4,200 µmol/s, 1,500W at 277VAC.
  • 1,225 µmol/m²/s average PPFD at 12 inches, peaking at 1,613 under the fixture — the highest canopy average in the flexible-arm family.
  • Two-channel control: UV and far-red on one dimmer, white and blue on the other, both 0-100%.
  • 4ft × 7ft flowering, 5ft × 8ft vegetative coverage from a 59.1"-long flexible-arm frame.
  • Deep-red-weighted vegetative spectrum — the DR spectral distribution carries a markedly stronger 660nm peak than the TF and TR fixtures.
  • 120-277VAC or 277-480VAC, 5.42A at 277V, power factor above 0.95.
  • Passive cooling to 40°C ambient; IP65, flicker-free, damp-location rated.
  • Five-year standard warranty, L90 beyond 50,000 hours.
In the room

What it looks like in use

1500W LED grow light
In use

Over a commercial flowering bench

Installed in a working commercial grow. Rated coverage: Flower 4ft x 7ft; Veg 5ft x 8ft.

led grow light controller
Group control

GC001 touchscreen

Schedules, per-channel levels, and live temperature, humidity and VPD — one controller runs up to 100 fixtures over RJ12.

Same platform

Choose your model

Model Power PPF Flowering footprint Avg PPFD @ 1 ft
DR 1500W PLUS 1500 W 4,200 µmol/s 4ft x 7ft 1,225 µmol/m²/s this page
DR 1060W PLUS 1060 W 2,968 µmol/s 4ft x 6ft 866 µmol/m²/s View →
Data

Specifications

Download spec sheet (PDF)

Power
1500 W
PPF
4,200 µmol/s
Spectrum
Full spectrum white (Samsung LM281B) + 450nm blue + 660nm deep red + 730nm far-red + 395nm UV
Control channels
2
Coverage
Flower 4ft x 7ft; Veg 5ft x 8ft
Input voltage
120-277VAC / 277-480VAC, 50/60Hz (rated input 110-277V)
Dimming
0-100% dimmer knob; two channels (UV+IR / white+blue) dimmable independently; RJ12 port for group control
IP rating
IP65
Rated lifetime
50,000 h
Warranty
5 years standard

Engineering data

Replaces
2250W HPS/MH
Average PPFD @ 1 ft
1,225 µmol/m²/s
Centre PPFD @ 1 ft
1,613 µmol/m²/s
Diode brands
Samsung & Osram
Diode configuration
Samsung LM281b, 450nm, 660nm, 730nm and 395nm chips
Beam angle
120 deg
Mounting height
6-24 in
Thermal management
Passive
Max ambient
40 °C
Power factor
>0.95
Ratings
Flicker-free, damp-location, dimmable, IP65
Packing
1 pc/carton, L1150 x W250 x H290 mm, 19.0 kg gross

Current draw by supply voltage

What the circuit is sized from when you plan how many fixtures share a breaker.

  • 110Vac 13.6A
  • 120Vac 12.5A
  • 220Vac 6.82A
  • 240Vac 6.25A
  • 277Vac 5.42A

PPFD distribution maps available with your quote.

Questions

Before you spec it

What do I give up moving from three channels to two?

Independent UV dosing. On the DR, UV and far-red share a dimmer, so you cannot ramp far-red into late flower while holding UV flat. If that is part of your protocol, take the TF 1600W PRO or TR 1000W PRO instead. If UV and far-red always move together in your recipe, the two-channel fixture is one fewer thing to get wrong at scale.

DR 1500W PLUS or TF 1600W PRO?

Close in output — 4,200 against 4,480 µmol/s — but different benches: 4ft × 7ft here, 4ft × 8ft for the TF. Then frame (flexible arm vs folding panel) and channels (two vs three). Match the footprint to your bench pitch first; the rest follows.

Can I run it alongside the smaller DR?

Yes. The DR 1060W PLUS is the same frame and two-channel scheme at 2,968 µmol/s over 4ft × 6ft — a common pairing where a room mixes 4ft × 7ft and 4ft × 6ft benches. Both group-control from one GC001.

How much current does a room of these draw?

5.42A per fixture at 277V, 12.5A at 120V, power factor above 0.95. At 1,500W each, connected load rather than circuit current is usually the planning constraint — worth modelling before you fix the fixture count.

Get in touch

Send dimensions, get a layout.

Room size, ceiling height, tier count and the PPFD you are targeting are enough to start. We come back with a fixture count, a room layout and a factory-direct price.

Request a quote

Six fields and a message — the sales team replies directly.