DR 1500W PLUS
High-output full-spectrum + UV/IR, 2-channel control
Factory-direct pricing. Send your room size and target PPFD for a layout recommendation with the quote.
- Photon flux (PPF)
- 4,200 µmol/s
- Input power
- 1500 W
- Flowering footprint
- 4ft x 7ft
- Ingress protection
- IP65
What we measured
The three artifacts a lighting plan is actually drawn from. Every figure below comes off our own spec sheet; where we do not have a measurement, the page says so instead of estimating.
Coverage & PPFD
Rated flowering footprint, 4 × 7 ft. Both readings are µmol/m²/s measured 1 ft from canopy (mounting range 6-24 in). The shading illustrates centre-to-edge falloff; it is not a measured grid. A full PPFD map at your mounting height comes with the quote.
2-channel spectrum
Full spectrum white (Samsung LM281B) + 450nm blue + 660nm deep red + 730nm far-red + 395nm UV. Each channel dims on its own — at the fixture or over group control.
Download the full spec sheet (PDF)What the DR 1500W PLUS is for
The highest-output flexible-arm fixture: 4,200 µmol/s over a 4ft × 7ft flowering bench, delivering 1,225 µmol/m²/s average at canopy. Two channels rather than three — UV and far-red move together against the white/blue base — which is the right simplification for production rooms running a fixed recipe at high intensity. 2,250W HPS replacement.
What you get
- 4,200 µmol/s, 1,500W at 277VAC.
- 1,225 µmol/m²/s average PPFD at 12 inches, peaking at 1,613 under the fixture — the highest canopy average in the flexible-arm family.
- Two-channel control: UV and far-red on one dimmer, white and blue on the other, both 0-100%.
- 4ft × 7ft flowering, 5ft × 8ft vegetative coverage from a 59.1"-long flexible-arm frame.
- Deep-red-weighted vegetative spectrum — the DR spectral distribution carries a markedly stronger 660nm peak than the TF and TR fixtures.
- 120-277VAC or 277-480VAC, 5.42A at 277V, power factor above 0.95.
- Passive cooling to 40°C ambient; IP65, flicker-free, damp-location rated.
- Five-year standard warranty, L90 beyond 50,000 hours.
What it looks like in use
Over a commercial flowering bench
Installed in a working commercial grow. Rated coverage: Flower 4ft x 7ft; Veg 5ft x 8ft.
GC001 touchscreen
Schedules, per-channel levels, and live temperature, humidity and VPD — one controller runs up to 100 fixtures over RJ12.
Choose your model
| Model | Power | PPF | Flowering footprint | Avg PPFD @ 1 ft | |
|---|---|---|---|---|---|
| DR 1500W PLUS | 1500 W | 4,200 µmol/s | 4ft x 7ft | 1,225 µmol/m²/s | this page |
| DR 1060W PLUS | 1060 W | 2,968 µmol/s | 4ft x 6ft | 866 µmol/m²/s | View → |
Specifications
- Power
- 1500 W
- PPF
- 4,200 µmol/s
- Spectrum
- Full spectrum white (Samsung LM281B) + 450nm blue + 660nm deep red + 730nm far-red + 395nm UV
- Control channels
- 2
- Coverage
- Flower 4ft x 7ft; Veg 5ft x 8ft
- Input voltage
- 120-277VAC / 277-480VAC, 50/60Hz (rated input 110-277V)
- Dimming
- 0-100% dimmer knob; two channels (UV+IR / white+blue) dimmable independently; RJ12 port for group control
- IP rating
- IP65
- Rated lifetime
- 50,000 h
- Warranty
- 5 years standard
Engineering data
- Replaces
- 2250W HPS/MH
- Average PPFD @ 1 ft
- 1,225 µmol/m²/s
- Centre PPFD @ 1 ft
- 1,613 µmol/m²/s
- Diode brands
- Samsung & Osram
- Diode configuration
- Samsung LM281b, 450nm, 660nm, 730nm and 395nm chips
- Beam angle
- 120 deg
- Mounting height
- 6-24 in
- Thermal management
- Passive
- Max ambient
- 40 °C
- Power factor
- >0.95
- Ratings
- Flicker-free, damp-location, dimmable, IP65
- Packing
- 1 pc/carton, L1150 x W250 x H290 mm, 19.0 kg gross
Current draw by supply voltage
What the circuit is sized from when you plan how many fixtures share a breaker.
- 110Vac 13.6A
- 120Vac 12.5A
- 220Vac 6.82A
- 240Vac 6.25A
- 277Vac 5.42A
PPFD distribution maps available with your quote.
Before you spec it
What do I give up moving from three channels to two?
Independent UV dosing. On the DR, UV and far-red share a dimmer, so you cannot ramp far-red into late flower while holding UV flat. If that is part of your protocol, take the TF 1600W PRO or TR 1000W PRO instead. If UV and far-red always move together in your recipe, the two-channel fixture is one fewer thing to get wrong at scale.
DR 1500W PLUS or TF 1600W PRO?
Close in output — 4,200 against 4,480 µmol/s — but different benches: 4ft × 7ft here, 4ft × 8ft for the TF. Then frame (flexible arm vs folding panel) and channels (two vs three). Match the footprint to your bench pitch first; the rest follows.
Can I run it alongside the smaller DR?
Yes. The DR 1060W PLUS is the same frame and two-channel scheme at 2,968 µmol/s over 4ft × 6ft — a common pairing where a room mixes 4ft × 7ft and 4ft × 6ft benches. Both group-control from one GC001.
How much current does a room of these draw?
5.42A per fixture at 277V, 12.5A at 120V, power factor above 0.95. At 1,500W each, connected load rather than circuit current is usually the planning constraint — worth modelling before you fix the fixture count.